Skip to content

Add support for reading raw resistances to ENS160#4

Open
coolnickname wants to merge 1 commit intoTimHanewich:masterfrom
coolnickname:master
Open

Add support for reading raw resistances to ENS160#4
coolnickname wants to merge 1 commit intoTimHanewich:masterfrom
coolnickname:master

Conversation

@coolnickname
Copy link

Officially only sensors 1 and 4 are supported according to the datasheet, but it seems like sensor 3 is also readable. Sensor 2 appears to always return 1.0 Ohm, but I included it anyway for completeness. The raw resistance of the MOX sensors is not compensated for humidity or temperature.

Officially only sensors 1 and 4 are supported according to the datasheet, but it seems like sensor 3 is also readable.
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant